Power & Protection Studies

Protecting Assets.
Ensuring Continuity.
Maximising Uptime.

ppa carries out detailed electrical power analysis and protection studies to ensure that power distribution systems operate safely and reliably under all conditions. Using ETAP software, our engineers deliver comprehensive studies that safeguard people, equipment, and critical infrastructure from electrical fault events. 

Power & Protection Studies Overview 

Our power studies encompass load flow analysis, short-circuit calculations, protection discrimination, arc flash assessment, and power quality evaluation. Each study is tailored to the project's specific network topology, equipment characteristics, and operational requirements, producing actionable recommendations and compliant documentation. 

We have extensive experience delivering power and protection studies for mission-critical data centres, financial institutions, and complex commercial developments. Our studies are produced in accordance with IEC 60909, IEEE 1584, and BS 7671 standards, and are accepted by major utility companies and regulatory bodies across EMEA. 

Untitled design (99).png
Untitled design (14).png

Scope of Service

  • Electrical load flow and power balance analysis 

  • Short-circuit and fault level calculations (IEC 60909) 

  • Protection relay coordination and discrimination studies 

  • Arc flash hazard analysis and incident energy assessment (IEEE 1584) 

  • Power quality and harmonic distortion analysis 

Power System Analysis

  • Load flow analysis under normal, maximum, and minimum demand conditions 

  • Voltage profile analysis across the distribution network 

  • Power factor correction assessment and capacitor bank sizing 

  • Unbalance and harmonic load analysis 

  • Generator synchronisation and load sharing studies 

Protection Studies

  • Protection relay grading and time-current coordination studies 

  • Full discrimination analysis from utility interface to final circuits 

  • Earth fault protection and residual current device coordination 

  • Differential protection studies for transformers and busbars 

  • Protection relay setting schedules and vendor coordination 

Arc Flash & Safety

  • Arc flash incident energy calculations to IEEE 1584 methodology 

  • Flash protection boundary and PPE category assignment 

  • Arc flash hazard labelling schedules for all switchgear 

  • Mitigation recommendations to reduce incident energy levels 

  • Safety documentation compliant with IEC 60079 and local regulations 

Design Process

Concept & Feasibility

Network data gathering, equipment specifications, and load schedule development. Definition of study scope and compliance standards applicable to the project. 

Schematic Design

Initial ETAP model build and preliminary load flow and fault studies. Early identification of protection gaps and system design recommendations. 

Detailed Design

Full study suite completed with confirmed equipment data — protection grading, arc flash, discrimination, and power quality reports produced. 

IFC Documentation

Formal study reports and protection relay settings schedules issued for construction, with full compliance documentation for client and regulatory records. 